二维码(扫一下试试看!) |
Determination of the Moisture Content in Cigarette Paper by Headspace-Karl Fischer Coulometric Method |
Received:December 19, 2023 |
DOI:10.11980/j.issn.0254-508X.2024.06.015 |
Key Words:cigarette paper moisture karl fischer coulometry method drying furnace |
Fund Project:浙江中烟工业有限责任公司2023年科技项目“卷烟纸对卷烟燃烧过程中烟碱迁移的影响机制”( ZJZY2023C001)。 |
|
Hits: 716 |
Download times: 543 |
Abstract:In this study, a headspace-Karl Fischer coulometric method was established to determine the moisture content in cigarette paper. By optimizing the experimental conditions such as heating temperature, titration time, sample shape and sample size, the moisture content in cigarette paper was quickly determined. The results showed that the optimum conditions for detecting the moisture content of cigarette paper were as follows: drying furnace temperature was 120 ℃, adopting delay time termination mode, titration time was 10 min, sample mass was 0.06 g. The recoveries of the method were 95.46%~104.99% and the relative standard deviations were 1.12%~4.07% at different spiked levels. Compared with oven method, halogen method and thermal conductivity detection by gas chromatography (GC-TCD) method, the determination results were close, and met the relevant requirements of GB/T 462—2008. The Headspace-Karl Fischer coulometric method could extract water more fully, and truly reflect the moisture content in the sample. Headspace-Karl Fischer coulometric method is simple, rapid, accurate and reliable, and suitable for batch analysis of moisture content in cigarette paper. |
View Full Text HTML View/Add Comment Download reader |