二维码(扫一下试试看!) |
Parameter Test and Optimization of Trim Squirt Control System of Paper Machine |
Received:September 09, 2022 |
DOI:10.11980/j.issn.0254-508X.2023.02.015 |
Key Words:paper machine trim squirt positioning deviation variable speed double dead zone numerical optimization |
Fund Project:广东机电职业技术学院高层次人才项目(Gccrcxm-202209);广东省普通高校重点科研项目(2022KQNCX178)。 |
Author Name | Affiliation | Postcode | LI Chao* | Guangdong Mechanical and Electronical College of Technology, Guangzhou, Guangdong Province, 510550 | 510550 | LEI Hailong | Mudanjiang Hengfeng Paper Co., Ltd., Mudanjiang, Heilongjiang Province, 157013 | 157013 | XU Kai* | Wuhan Institute of Shipbuilding Technology, Wuhan, Hubei Province, 430050 | 430050 | GENG Qingling | Guangdong Mechanical and Electronical College of Technology, Guangzhou, Guangdong Province, 510550 | 510550 | SUN Fuming | Mudanjiang Hengfeng Paper Co., Ltd., Mudanjiang, Heilongjiang Province, 157013 | 157013 | ZHANG Baoyan | School of Mechanical Engineering, Jiamusi University, Jiamusi, Heilongjiang Province, 154007 | 154007 | WANG Haixiang | School of Mechanical Engineering, Jiamusi University, Jiamusi, Heilongjiang Province, 154007 | 154007 |
|
Hits: 2181 |
Download times: 1198 |
Abstract:In order to redurce the deviation between the final stop position and the set target threading position of the Trim Squirt, the problem of reasonable selection of control low dead zone value was studied using variable speed double dead zone method based on the trim squirt movement control system, taking control low dead zone as an example. Based on field test data and the polynomial fitting optimization method, the mathematical model of trim squirt displacement and control low dead zone value were established, finding out the reasonable ravge of control low dead zone value, and the control low dead zone value was selected, which was verified in production application. The results showed that when the control low dead zone value was 30, the trim squirt positioning deviation was the smallest, and the deviation from the set position was 6 mm, with the error of -0.80%. |
View Full Text HTML View/Add Comment Download reader |
|
|
|