本文二维码信息
二维码(扫一下试试看!)
Design of Selective Catalytic Reduction Denitrification System For Biomass Boiler Based on CFD Simulation
Received:September 07, 2025  Revised:December 01, 2025
DOI:10.11980/j.issn.0254-508X.2026.05.018
Key Words:SCR denitrification  numerical simulation  flow field
Author NameAffiliationPostcode
WU Jing* 1China Light-Industry International Engineering Co., Ltd., Beijing, 100026 100026
JIAO Sha 2Zhejiang Hailu Zhongling lenergy Technology Co., Ltd., Hangzhou, Zhejiang Province, 310051 310051
LUO Zunfu 1China Light-Industry International Engineering Co., Ltd., Beijing, 100026 100026
ZHANG Yongzhi 1China Light-Industry International Engineering Co., Ltd., Beijing, 100026 100026
Hits: 974
Download times: 122
Abstract:A three-dimensional model of flue gas denitrification system of 150 t/h biomass boiler was established by CFD simulation technology to evaluate the flow field distribution of selective catalytic reduction (SCR) denitrification system reactor and the flue gas. The design of the guide plate, ammonia injection grille, rectifier grille, and reactor were optimized to ensure that the key evaluation indicators such as flue gas velocity deviation, velocity deviation angle, concentration deviation, temperature deviation, and pressure distribution all met the design requirements. A reasonable design scheme for the denitrification system and flue was established, and the external structure of the flue gas denitrification system, as well as the shapes and layout of inlet flue, ammonia injection system, rectifier, etc. were determined.
View Full Text  HTML  View/Add Comment  Download reader