 二维码(扫一下试试看!) |
| Research on Thermal Conductivity of Cigarette Paper for Heated Tobacco Based on Transient Plane Source Method |
| Received:September 14, 2024 |
| DOI:10.11980/j.issn.0254-508X.2025.01.010 |
| Key Words:cigarette paper heated tobacco thermal conductivity coefficients transient plane source method |
| Fund Project:中国烟草总公司科技项目(110202402030);上海新型烟草制品研究院有限公司科技项目(Z2024-002Z);上海烟草集团有限责任公司科技项目(K2024-1-022P)。 |
| Author Name | Affiliation | Postcode | | WANG Gang | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | WANG Yuqing | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | BU Zichen | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 | 201315 | | WANG Xu* | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | YANG Jing | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | FEI Ting* | Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | XU Gangqiang | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 Shanghai Tobacco Group Co., Ltd., Shanghai, 201315 | 201315 | | WANG Qian | Shanghai New Tobacco Product Research Institute Co., Ltd., Shanghai, 201315 | 201315 | | GUO Lei | Gansu Tobacco Industry Co., Ltd., Lanzhou, Gansu Province, 730050 | 730050 | | LI Shan | Gansu Tobacco Industry Co., Ltd., Lanzhou, Gansu Province, 730050 | 730050 |
|
| Hits: 3372 |
| Download times: 1096 |
| Abstract:In order to investigate the thermal conductivity of cigarette paper for heated tobacco, transient plane source method was used to detect the thermal conductivity of cigarette paper, and lab methodology verification was carried out to verify and study the effects of conventional physical indexes, calendering treatment, calcium carbonate addition, fiber raw material types, anti-penetration treatment, and temperature on the thermal conductivity of cigarette paper. The results showed that the intraday and interday precision of transient plane source method for measuring the thermal conductivity coefficients of cigarette paper were both lower than 4%. The thermal conductivity coefficients of cigarette paper had a significant positive correlation with the tightness and a negative correlation with the air permeability. After calendering, the fiber contact in cigarette paper was closer and the gap was smaller, the thickness and air permeability of cigarette paper decreased, the tightness increased, and the thermal conductivity of cigarette paper was significantly enhanced. The larger amount of calcium carbonate in cigarette paper, the larger thickness and air permeability of cigarette papers and the smaller tightness, the stronger the thermal conductivity. The thermal conductivity coefficients were different for the cigarette paper prepared from different fiber raw materials such as hemp pulp and wood pulp. The thermal conductivity coefficients of cigarette paper after anti-permeation treatment (modified starch coating amount of 0~0.17%) had no obvious change. The thermal conductivity of cigarette paper increased with the increase of temperature in the range of 22~250 ℃. |
| View Full Text HTML View/Add Comment Download reader |
|
|
|