JING Liming* College of Environmental Science and Engineering Shannxi University of Science & TechnologyXi’an Shaanxi Province 710021
China Light Industry Water Pollution Control Engineering Center Xi’an Shaanxi Province 726300 
726300
LIU Shuang College of Environmental Science and Engineering Shannxi University of Science & TechnologyXi’an Shaanxi Province 710021 710021
AI Shuang College of Environmental Science and Engineering Shannxi University of Science & TechnologyXi’an Shaanxi Province 710021 710021
DANG Yidi College of Environmental Science and Engineering Shannxi University of Science & TechnologyXi’an Shaanxi Province 710021
Water Conservancy Bureau of Shangnan County Shangluo Shaanxi Province 726399 
726399
MA Lan College of Environmental Science and Engineering Shannxi University of Science & TechnologyXi’an Shaanxi Province 710021
Xinjiang Municipa Research Institute of Environmental Protection Urumqi Xinjiang Uygur Autonomous Region 830000 
830000
Hits: 1093
Download times: 817
Abstract:In this study, the pollutant characteristics from element chlorine free (ECF) bleaching bamboo pulp were analyzed, the acute toxicity of the wastewater was comprehensively evaluated, and the degradation of toxic organic chloride in wastewater was also discussed by Ti/IrO2-RuO2 coating electrode. Wastewater characteristic analysis showed that the pollutants were mainly generated in D0 stage of ECF bleaching process, contributing chemical oxygen demand (COD) and absorbable organic halogen (AOX) 71.8% and 73.4% respectively, and its acute toxicity (EC50 of 27.7%) was slightly more than Eop wastewater (EC50 of 44.4%), but both of which were in the moderate toxicity grade , organic chlorides played more tribute to wastewater’s toxicity. The results showed the pollution load of wastewater from ECF bleaching bamboo pulp was greatly decreased with Ti/IrO2-RuO2 coating electrode oxidization. With the conditions of voltage 7.0 V and the electrolysis time 240 min, the CODCr removal rate of wastewater from D0 stage, Eop stage and the mixed wastewater of D0 and Eop were 57.7%, 37.5% and 43.5%, the decolored rate were 90.2%, 82.3% and 83.1% respectively. And better toxic organic chloride (AOX) degradation efficiencies were 66.3% ,70.2% and 100% respectively, the toxicity grade reached low toxicity from moderate toxicity, and the Eop wastewater indicated non-toxic level.