 二维码(扫一下试试看!) |
| Engineering Design of Wastewater Treatment towards Carbonless Copy Paper Coating |
| Received:December 02, 2021 |
| DOI:10.11980/j.issn.0254-508X.2022.03.015 |
| Key Words:wastewater of carbonless copy paper coating wastewater treatment engineering design |
| Author Name | Affiliation | Postcode | | LIU Yingyao* | State Key Lab of Pulp and Paper Engineering, South China University of Technology,Guangzhou, Guangdong Province, 510640 | 510640 | | HE Yuna | State Key Lab of Pulp and Paper Engineering, South China University of Technology,Guangzhou, Guangdong Province, 510640 | 510640 | | CHEN Gang | State Key Lab of Pulp and Paper Engineering, South China University of Technology,Guangzhou, Guangdong Province, 510640 | 510640 | | FANG Zhiqiang | State Key Lab of Pulp and Paper Engineering, South China University of Technology,Guangzhou, Guangdong Province, 510640 | 510640 | | WANG Qinwen | State Key Lab of Pulp and Paper Engineering, South China University of Technology,Guangzhou, Guangdong Province, 510640 | 510640 |
|
| Hits: 5485 |
| Download times: 2900 |
| Abstract:Taking a carbonless copy paper manufacturer in Guangxi as an example, the wastewater of carbonless copy paper coating was treated with a combination of primary physicochemical method (high-efficiency wastewater purifier), biochemical method (tower biological filter) and deep oxidation (Fenton oxidation).The results showed that CODCr removal rate of this process was 97.8%, the BOD5 removal rate was 98.3%, and the SS removal rate was 95.9% for wastewater of carbonless copy paper coating.All of quality indicators of the treated wastewater met the discharge standards stipulated in GB 3544—2008. |
| View Full Text HTML View/Add Comment Download reader |
|
|
|