本文二维码信息
二维码(扫一下试试看!)
Chloride Removal in Recovery Boiler Operation by Using Ion Exchange Technology
  
DOI:10.11980/j.issn.0254-508X.2012.08.006
Key Words:ESP dust  amphoteric ion exchange resin  chloride ion
Fund Project:本课题为温州市科技计划项目(H20100034)。
Author NameAffiliation
薛 融1 1.陕西科技大学陕西西安710021 
李运涛1 1.陕西科技大学陕西西安710021 
欧阳春2 2.中国海诚工程科技股份有限公司研发中心上海201702 
贺 磊2 2.中国海诚工程科技股份有限公司研发中心上海201702 
杨娇2 2.中国海诚工程科技股份有限公司 
陈均志3 3.浙江温州轻工研究院浙江温州325003 
徐 斌4 4.浙江争光实业股份有限公司浙江杭州311106 
Hits: 4718
Download times: 1281
Abstract:A method of removing Cl- and recovering SO2-4 in carryover particles in recovery boiler operation with amphoteric ion-exchange resin which was developed in lab was presented. The results showed that, the removing rate of Cl- was 85% and the retention rate of SO2-4 was 70% under the optimal conditions of ESP dust concentration 200 g/L, flow rate 3 m/h and temperature 45℃.