 二维码(扫一下试试看!) |
| Chloride Removal in Recovery Boiler Operation by Using Ion Exchange Technology |
| |
| DOI:10.11980/j.issn.0254-508X.2012.08.006 |
| Key Words:ESP dust amphoteric ion exchange resin chloride ion |
| Fund Project:本课题为温州市科技计划项目(H20100034)。 |
| Author Name | Affiliation | | 薛 融1 | 1.陕西科技大学,陕西西安,710021 | | 李运涛1 | 1.陕西科技大学,陕西西安,710021 | | 欧阳春2 | 2.中国海诚工程科技股份有限公司研发中心,上海,201702 | | 贺 磊2 | 2.中国海诚工程科技股份有限公司研发中心,上海,201702 | | 杨娇2 | 2.中国海诚工程科技股份有限公司 | | 陈均志3 | 3.浙江温州轻工研究院,浙江温州,325003 | | 徐 斌4 | 4.浙江争光实业股份有限公司,浙江杭州,311106 |
|
| Hits: 9562 |
| Download times: 2562 |
| Abstract:A method of removing Cl- and recovering SO2-4 in carryover particles in recovery boiler operation with amphoteric ion-exchange resin which was developed in lab was presented. The results showed that, the removing rate of Cl- was 85% and the retention rate of SO2-4 was 70% under the optimal conditions of ESP dust concentration 200 g/L, flow rate 3 m/h and temperature 45℃. |