本文二维码信息
二维码(扫一下试试看!)
Comparative Analysis of Fluorescence Intensity and Fluorescent Migration in Paper
  
DOI:10.11980/j.issn.0254-508X.2011.04.004
Key Words:brightness  fluorescence spectrophotometry  paper  fluorescent material migration
Author NameAffiliation
刘 峻 上海市质量监督检验技术研究院上海200233 
徐振华 上海市质量监督检验技术研究院上海200233 
闫 辉 上海市质量监督检验技术研究院上海200233 
秦紫明 上海市质量监督检验技术研究院上海200233 
章若红 上海市质量监督检验技术研究院上海200233 
徐德佳 上海市质量监督检验技术研究院上海200233 
Hits: 5954
Download times: 1857
Abstract:17 samples in which fluorescence was not meet the regulation requirement based on the analysis following the analysis method for food packaging base paper hygiene GB / T 5009.78—2003 were tested furtherly. Fluorescence intensity and fluorescent migration were tested by fluorescence spectrophotometry and brightness instrument respectively, using fluorescent whitening agent VBL as the standard material. When the concentrations of VBL were from 0 to 4.0 mg/L,they had a linear relationship with the emitted fluorescence intensity. The experiments showed that different methods derived different results. The fluorescent migration may be affected by basis weight of the paper and the manufacturing process. The brightness method, which can be used to test the fluorescent substance in the surface of paper, can not reflect the migration of fluorescent.
View Full Text  HTML  View/Add Comment  Download reader