|
二维码(扫一下试试看!) |
高压碱回收炉焙炉水冷壁内管结垢及腐蚀分析 |
Corrosion and Pipe Scale Analysis of High Pressure Alkali Recovery Boiler’s Water Wall Tubes |
收稿日期: |
DOI:10.11980/j.issn.0254-508X.2016.10.004 |
关键词: 碱回收炉 水冷壁 腐蚀 结垢 |
Key Words:alkali recovery boiler water wall pipes corrosion scaling |
基金项目: |
|
摘要点击次数: 6903 |
全文下载次数: 1943 |
摘要:采用X射线衍射仪(XRD)、场发射扫描电子显微镜(FESEM)、金相显微镜分析了碱回收炉水冷壁管腐蚀面的元素组成,以找出腐蚀原因,并提出改善建议。分析检测结果表明,腐蚀以氯腐蚀为主兼有碱腐蚀,氯腐蚀一旦发生即不可逆转。建议从酸洗、水质、锅炉运行及监控方面进行改善,从而提高锅炉安全运行的可靠性。 |
Abstract:Corrosion analysis of recovery boiler’s water wall pipes found that the corrosion was maily caused by chlorine, as well caused by alkali in some degree, the paper provided suggestions for relieving corrosion and scaling from the aspects of acid pickling, water treatment, boiler running and monitor, accordingly improving safe dependability of the boiler. |
查看全文 HTML 查看/发表评论 下载PDF阅读器 |
|
|
|