本文二维码信息
二维码(扫一下试试看!)
Faults Analysis and Maintenance of Electric Drive System of Paper Machine
  
DOI:10.11980/j.issn.0254-508X.2012.03.009
Key Words:paper machine  drive system  fault analysis  troubleshooting  ABB frequency converter  vector torque control
Author NameAffiliation
彭迪辉 湖南泰格林纸集团沅江纸业湖南沅江413100 
Hits: 4486
Download times: 1981
Abstract:Nowadays paper machine drive systems of DC main shaft and SCR DC drive control unit have been gradually replaced by AC variable frequency and speed drive. From the small range variable speed drive to high precision, fast response, wide range variable speed drive, from the single drive to multiple segments coordination, PROFIBUS fieldbus protocol format is used to achieve communication and control of frequency converter, which is with high efficient drive and good control characteristics, and is widely used in papermaking industry. Based on maintenance practice, the author analyzed the reasons of speed instability, rundownly stop of some part and defects of inverter hardware.
View Full Text  HTML  View/Add Comment  Download reader