IC厌氧反应器处理OCC废水运行效率研究
Operational Efficiency of IC Anaerobic Reactor for OCC Wastewater Treatment
收稿日期:2024-04-19  
DOI:10.11980/j.issn.0254-508X.2024.08.025
关键词:  IC厌氧反应器  OCC废水  厌氧颗粒污泥  水力停留时间
Key Words:IC anaerobic reactor  OCC wastewater  anaerobic granular sludge  hydraulic retention time
基金项目:
作者单位邮编
李雄林 山东博汇纸业股份有限公司,山东淄博,256400 256400
魏庆伟* 山东博汇集团有限公司,山东淄博,256400 256400
摘要点击次数: 502
全文下载次数: 490
摘要:某OCC制浆造纸企业新建了一座容积2 900 m3的IC厌氧反应器,并引入来自同类废水的厌氧颗粒污泥。启动21天后,IC厌氧反应器运行效果达到设计负荷,OCC制浆造纸废水处理量为15 000 m3/d,CODCr处理量为50 000 kg/d,CODCr去除率72%~86%,出水挥发性脂肪酸稳定保持在30~110 mg/L,IC厌氧反应器在较短时间内完成效率提升。
Abstract:A new 2 900 m3 IC anaerobic reactor had been built by an OCC papermaking company, and the anaerobic granular sludge from the same kind of wastewater was introduced. After starting up for 21 d, the IC anaerobic reactor reached the design loading and could treat OCC wastewater for 15 000 m3/d with total CODCr for 50 000 kg/d. The CODCr removal rate was 72%~86%, and the VFA of reactor outlet water remained 30~110 mg/L, indicating the new IC anaerobic reactor can improve efficiency in a short time.